IFP Control Monitoring and Motion Compensation

The Motas fall pipe control, monitoring and motion compensation system operates the complete inclined fall pipe installation from one console on the bridge: deployment and recovery, motion-compensated rock dumping and the rock feed system. The tip of the fall pipe follows the course set in the vessel’s DP system, while sensors on every moving part give the operator continuous insight into pipe position and loads. Load limiters and interlocks protect the equipment, so rock is placed accurately and safely.

Deployment and recovery

  • Automatic: deployment and recovery in pre-defined steps, step by step or continuous
  • Manual: operator-controlled, with interlocks that prevent damage to the equipment
  • Service: each component operated individually, for maintenance only

Motion compensation

The fall pipe pivots in two directions to actively compensate for the roll and pitch of the vessel. Encoders in the longitudinal and transverse cylinders measure the pipe angles continuously, so the pipe tip stays on course during dumping, also in a swell.

Rock dumping

  • Automatic dumping: the pipe tip follows the course set in the DP system, with an adjustable dumping offset, fully motion compensated for roll and pitch
  • Manual dumping: rigid pipe, operated with setpoints relative to the vessel or with an optional joystick
  • Integrated control of the hopper and apron feeder, with variable-speed drives to match the rock supply to the dumping process

Monitoring and protection

  • Pipe position and angles measured by encoders in all cylinders, winches and the main pivot
  • Load limiters on every motion: the operator is warned first; on overload the rock supply stops automatically and the load is reduced
  • Production indication by belt weighing on the apron feeder and density measurement in the fall pipe
  • Interlock page for fault finding and logging of all parameter changes

Proven and serviceable

Industrial PLC with a multitouch HMI on the bridge and a portable local control panel. Sensors on deck are subsea rated. HMI screens are tested with the client in a software simulation FAT before delivery, and remote access allows fast support. After delivery, the client receives full access to the software.